Login
Quotation list
Shopping cart
Get in contact +31(0)26 370 6830
Temperature
Temperature

Temperature Sensors for Process Industry | Ebora

Temperature sensors for industrial process measurement Temperature sensors are used when you need to continuously measure, monitor or control temperature in gases, liquids or solids. The sensor converts temperature changes into an analogue signal (4–20 mA, 0–10 V) or digital signal that your PLC, transmitter or logger processes directly. Whether it concerns overheat protection, quality control or process optimisation in the process industry: the right sensor prevents downtime, energy waste and unwanted quality deviations.

What is a temperature sensor?

A temperature sensor detects temperature through physical principles such as expansion (bimetal), resistance (RTD, thermistor) or thermoelectric voltage (thermocouple). The measuring principle determines the signal type: voltage, current or resistance. The sensor forms part of integrated process instrumentation and is in industrial installations almost always combined with a transmitter for remote signal processing. In addition to temperature, pressure and flow are measured in complex processes via a pressure sensor and flow meter for a complete process overview.

How does a temperature sensor work?

Depending on the type, the sensor responds to a temperature rise as follows:
  • Thermocouple: voltage is generated between two different metals (Seebeck effect)
  • RTD (Pt100, Pt1000): resistance of a platinum coil increases linearly with temperature
  • Thermistor (NTC/PTC): ceramic resistance changes exponentially — NTC for sensitive low-temperature measurement, PTC for protection circuits
  • Thermostat: bimetal bends and switches mechanically at a settable point
  • Non-contact IR sensor: infrared radiation provides a voltage signal without physical contact with the medium
Price
to
Filter price
Brands
Model
Material
Mat. measuring element
Measuring insert diameter
Temperature range
Filter
Page 2 of 59 (1394 results)
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
Display:
Sort:
IFM Temperature cable sensor with process connection, TS9256
100,90 122,09 Incl. VAT
Product code: 10177364
IFM Temperature sensor with process connection, TM4361
128,70 155,73 Incl. VAT
Product code: 10177472
IFM Temperature transmitter with display, TD2277
281,10 340,13 Incl. VAT
Product code: 10177533
IFM Temperature transmitter with display, TD2901
295,10 357,07 Incl. VAT
Product code: 10177781
IFM Temperature transmitter with display, TD2933
300,00 363,00 Incl. VAT
Product code: 10178299
IFM Temperature transmitter with display, TD2267
277,40 335,65 Incl. VAT
Product code: 10178447
IFM Temperature transmitter with display, TD2801
280,80 339,77 Incl. VAT
Product code: 10176680
IFM Temperature transmitter with display, TD2263
277,40 335,65 Incl. VAT
Product code: 10178268
Spirax Sarco Temp. range: -15/+50C<br />Capilair: 4 mtr<br />
1.145,96 1.386,61 Incl. VAT
Product code: AC-168702
IFM Temperature transmitter, TAA131
337,00 407,77 Incl. VAT
Product code: 10175552
IFM Temperature transmitter, TAA431
353,30 427,49 Incl. VAT
Product code: 10174173
IFM Temperature cable sensor with bolt-on sensor, TS522A
151,90 183,80 Incl. VAT
Product code: 10176218
IFM Temperature cable sensor with process connection, TS2289
60,60 73,33 Incl. VAT
Product code: 10172161
IFM Temperature sensor with process connection, TM4901
139,30 168,55 Incl. VAT
Product code: 10174894
IFM Temperature probe sensor, TT3291
118,30 143,14 Incl. VAT
Product code: 10175908
IFM Temperature sensor with process connection, TM4331
118,20 143,02 Incl. VAT
Product code: 10175985
IFM Temperature cable sensor with screw-in sensor, TS0759
86,50 104,67 Incl. VAT
Product code: 10174000
IFM Temperature transmitter with drift detection, TAD991
701,10 848,33 Incl. VAT
Product code: 10175064
IFM Temperature sensor with process connection, TM4511
140,90 170,49 Incl. VAT
Product code: 10175754
IFM Temperature transmitter with drift detection, TAD981
701,10 848,33 Incl. VAT
Product code: 10175844
IFM Temperature transmitter with display, TD2913
296,40 358,64 Incl. VAT
Product code: 10174911
IFM Temperature transmitter with display, TD2231
266,60 322,59 Incl. VAT
Product code: 10175866
IFM Temperature probe sensor, TT2250
105,80 128,02 Incl. VAT
Product code: 10176184
Display:
Sort:
Page 2 of 59 (1394 results)
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
Filter

Temperature sensors

What types of temperature sensors are there?

Broadly, we distinguish two groups: sensors for continuous measurement with an electrical output signal (thermocouples, RTDs, thermistors, IR sensors) and switching elements for simple on/off control (thermostats). The right choice depends on measuring range, accuracy, response time, process conditions and the desired interface with your control system.

Thermocouple

Fast-responding and compact, with a wide measuring range from -200 °C to +2000 °C. Common types are K (NiCr–Ni) for general industrial use and J (Fe–CuNi) for lower temperatures. Use this type when the process reaches extreme temperatures or a fast response is required.

RTD – Resistance temperature detector (Pt100 / Pt1000)

High accuracy and excellent linearity in the range of -200 °C to +600 °C. Choose an RTD when signal quality and long-term stability are paramount, for example in laboratories or the process industry. The Pt1000 is less sensitive to cable resistance and therefore suited for longer cable runs.

Thermistor

NTC for very fast response at low temperatures (-50 °C to +150 °C), used in HVAC and cooling installations. PTC for protection circuits where resistance increases sharply when a threshold temperature is exceeded.

Thermostat

Electromechanical switch with bimetal element. No continuous signal, but direct on/off switching at a settable point. Used in boiler and HVAC installations where simple control is sufficient.

Non-contact IR sensor

Measures surface temperature via infrared radiation without physical contact. Use this type when the medium is moving, hazardous or when contact is technically not possible.

Comparison: which type of temperature sensor suits your application?


Type Measuring range Accuracy Response time Application
Thermocouple -200 to +2000 °C Moderate Fast High temperatures, metal industry
RTD (Pt100/Pt1000) -200 to +600 °C High Average Process industry, laboratories
Thermistor (NTC) -50 to +150 °C Very high (narrow range) Very fast HVAC, cooling installations
Thermostat Settable point Switching Slow Boilers, simple control
IR sensor Depending on type Moderate Very fast Surface measurement, moving parts

How do you install a temperature sensor?

Contact types (thermocouple, RTD) are installed in a protection tube or thermowell in the pipework, with sufficient insertion length for a representative measurement. If the insertion length is too short, ambient temperature influences the measurement result through conduction losses along the protection tube.
Points to consider during selection and installation:
  • Choose the insertion length based on pipe diameter and flow velocity
  • Use vibration-resistant mounting under mechanical load
  • Ensure correct sealing under overpressure or with aggressive media
  • For panel or machine construction, M12 mounting is standard
IR sensors are installed in line of sight with the correct spot size, at a distance according to the D:S ratio of the optics. Compensate for the emissivity of the surface being measured and avoid steam or dust in the measurement path.

Temperature sensors in the process industry

In the process industry, temperature sensors are used for monitoring reactors, heat exchangers, steam lines and cooling installations. RTDs are combined with transmitters that deliver a 4–20 mA or IO-Link signal to the PLC system. In complex installations, turbidity sensors are additionally used for quality monitoring of liquids alongside temperature and pressure measurements — enabling integrated process instrumentation where deviations are detected immediately.
Select your temperature sensor based on measuring range, process connection and signal type (Pt100, Pt1000, 4–20 mA, IO-Link) or request a quote directly. Unsure which type is right for your application? Our process instrumentation specialists advise on type, range and housing — schedule a free consultation today.

Frequently asked questions about temperature sensors



What is the function of a temperature sensor?

A temperature sensor converts temperature differences into an electrical signal that your control system or logger reads. This allows you to regulate processes stably, set alarms and detect quality deviations in time. Reliable temperature measurement prevents overheating, energy waste and unnecessary downtime.

When do I choose a thermocouple instead of an RTD?

Choose a thermocouple when your process temperature exceeds +600 °C, when a fast response time is required or when a compact design is needed. An RTD (Pt100/Pt1000) is the better choice when high accuracy and long-term signal stability are decisive within a range of -200 °C to +600 °C.

How do I know if my temperature sensor is faulty?

Symptoms include an absent or deviating signal. With an RTD or thermistor, an illogical ohm value indicates an open or short circuit. With a thermocouple, a missing or unrealistic millivolt output points to a fault. Compare the reading with a certified reference thermometer or use a calibrator. Also check connectors, terminals and cable breaks — many transmitters automatically display a fault message or error code.

What is the D:S ratio of an IR sensor?

The D:S ratio (distance-to-spot) indicates the size of the measurement spot at a given distance. A D:S of 10:1 means the sensor measures a spot of 1 cm diameter at 10 cm distance. The higher the ratio, the smaller the spot at greater distance — enabling more accurate measurement of smaller objects.

Where do I install a temperature sensor in my system?

Install contact sensors in a thermowell or immersion socket in the pipework, with sufficient insertion length and flow for a representative measurement. IR sensors are mounted in line of sight at the correct distance according to the optics, free from steam or dust. For panel or machine construction, M12 mounting is standard.

Shopping cart

Quotation list

Clear filters

Filter

&nspb;

Cancel